Catalog HONEYWELL


SEARCH YOUR PRODUCT IN THE CATALOG

 
 

111 products

9602-6500

(In Stock)

HIDROGEN FLUORIDE GAS SENSOR 9 MOD. MST SENSOR HF 0-10PPM

Info / Ask for Price

WEATHERPROOF CAP FOR USE WITH TOXIC DETECTOR INCLUDING REMOTE GASSING NOZZLE (FOR SENSEPOINT, SIGNALPOINT, SATELLITE (WITH ADAPTER), XNX MPD AND SERIES 2000)

Info / Ask for Price

02000-A-1640

(In Stock)

WEATHERPROOF CAP FOR USE WITH COMBUSTIBLE DETECTOR INCLUDING REMOTE GASSING NOZZLE (FOR SENSEPOINT, SIGNALPOINT, SATELLITE (WITH ADAPTER), XNX MPD AND SERIES 2000)

Info / Ask for Price

RM7888A1019

(In Stock)

BURNER CONTROL: RM7888A1019 BURNER CONTROL 120V 50/60 HZ LIMITS COMPLETE & AT LOW FIRE INPUTS. PILOT HOLD AND RETURN TO PILOT. AIR VALVE CONTROL DURING STANDBY. 4 SEC DSI. RM7888A1019 BY HONEYWELL IS A MICROPROCESSOR-BASED INTEGRATED BURNER CONTROL FOR INDUSTRIAL PROCESS SEMI-AUTOMATICALLY FIRED GAS, OIL, COAL, OR COMBINATION FUELS FOR SINGLE AND MULTIPLE BURNER APPLICATIONS. PROVIDES LEVEL OF SAFETY, FUNCTIONAL CAPABILITY AND FEATURES BEYOND CONVENTIONAL CONTROLS. ... SEE MORE ABOUT RM7888A1019 HERE EXPLODED IMAGE ABOVE SIMILAR TO RM7888A1019 SHOWS ADDITIONAL REQUIRED COMPONENTS. EXAMPLES OF SUCH COMPONENTS ARE Q7800A,B UNIVERSAL WIRING SUBBASES. R7847, R7848, R7849, R7851, R7852, R7861, OR R7886 FLAME SIGNAL AMPLIFIER.*RESTRICTED ITEM

Info / Ask for Price

RM7890A1056

(In Stock)

BURNER CONTROL: RM7890A1056 MICROPROCESSOR-BASED INTEGRATED PRIMARY BURNER CONTROL FOR AUTOMATICALLY FIRED GAS, OIL OR COMBINATION FUEL SINGLE BURNER APPLICATIONS.

Info / Ask for Price

RM7898A1000

(In Stock)

BURNER CONTROL: RM7898A1000 INTEGRATED FULL-FUNCTION PRIMARY BURNER CONTROL FOR GAS, OIL, OR COMBINATION FUEL SINGLE BURNER APPLICATIONS. INCLUDE PROGRAMMABLE POST PURGE AND VALVE PROVING FEATURE. REQUIRES S7800A1142 DSIPLAY TO PROGRAM VPS AND POST PURGE FEATURES.

Info / Ask for Price

L404F1102

(In Stock)

CONTROL: L404F1102 PRESSURETROL AUTO RECYCLE, 10 PSI TO 150 PSI. PROVIDE CONTROL OF STEAM, AIR, NON-COMBUSTIBLE GASES OR NON-CORROSIVE FLUIDS WITH AUTOMATIC LIMIT PROTECTION FOR PRESSURE SYSTEMS UP TO 300 PSI.

Info / Ask for Price

C7232A1008

(In Stock)

CONTROLLER: C7232A1008 CARBON DIOXIDE (CO2) SENSORS BY HONEYWELL ARE STAND-ALONE CARBON DIOXIDE (CO2) SENSORS FOR USE IN DETERMINING VENTILATION NECESSITY WITH HVAC CONTROLLERS. SENSOR MEASURES CO2 CONCENTRATION IN VENTILATED SPACE OR DUCT. SENSORS ARE USED IN VENTILATION AND AIR CONDITIONING SYSTEMS TO CONTROL AMOUNT OF FRESH OUTDOOR AIR SUPPLIED TO MAINTAIN ACCEPTABLE LEVELS OF CO2 IN SPACE. LCD THAT PROVIDES SENSOR READINGS AND STATUS INFORMATION. NON-DISPERSION-INFRARED (NDIR) TECHNOLOGY USED TO MEASURE CARBON DIOXIDE GAS. GOLD-PLATED SENSOR PROVIDES LONG-TERM CALIBRATION STABILITY. C7232 PROVIDES VOLTAGE OR CURRENT OUTPUT BASED ON CO2 LEVELS. SPST RELAY OUTPUT. USED FOR CO2 BASED VENTILATION CONTROL (DEMAND CONTROL VENTILATION (DCV)). AUTOMATIC BACKGROUND CALIBRATION (ABC) ALGORITHM BASED ON LONG-TERM EVALUATION REDUCES REQUIRED TYPICAL ZERO-DRIFT CHECK MAINTENANCE.

Info / Ask for Price

Y8610U4001

(In Stock)

ELECTRONIC IGNITION SYSTEM KIT: Y8610U4001 ELECTRONIC IGNITION SYSTEM KIT. Y-PACK CONTAINING S8610U3009 AND VR8204A2142 WITH 1/2 INCH BY 1/2 INCH INLET/OUTLET, FLANGE KIT, LP CONVERSION KIT.Y8610U4001 ELECTRONIC IGNITION SYSTEM BY HONEYWELL IS A COMPLETE KIT CONVERTING CONVENTIONAL STANDING PILOT SYSTEM TO INTERMITTENT PILOT SYSTEM. FOR USE WITH 24 VAC GAS-FIRED ATMOSPHERIC FURNACES, BOILER AND HEATING APPLIANCES. FEATURES: • Y8610F KITS ARE FOR USE WITH NATURAL GAS ONLY: CONTINUOUS TRAIL FOR IGNITION UNTIL PILOT LIGHTS OR SYSTEM IN SHUTDOWN MANUALLY. • Y8610U KITS ARE FOR USE WITH NATURAL OR LP GAS: PROVIDES 100 PERCENT PILOT GAS SHUTOFF IF PILOT FAILS TO LIGHT; AFTER 6-MINUTE DELAY, TRIAL FOR IGNITION IS REPEATED. • IGNITION TRAIL/DELAY SEQUENCE IS REPEATED UNTIL APPLIANCE LIGHTS OR CALL FOR HEAT IS REMOVED.

Info / Ask for Price

C7061A1012

(In Stock)

FLAME DETECTOR: C7061A1012. A DYNAMIC SELF CHECKING FLAME DETECTOR FOR SENSING UV RADIATION GENERATED BY COMBUSTION OF GAS, OIL, OR OTHER FUELS. USE WITH R7861A AMPLIFIER. AMBIENT TEMPERATURE RATING -40 TO 175F.

Info / Ask for Price

C7012E1245

(In Stock)

FLAME SENSOR: C7012E1245 120 VAC FLAME SENSOR, ULTRAVIOLET, PURPLE PEEPER, SELF-CHECKING, WITH HOT REFRACTORY TUBE. SENSE ULTRAVIOLET RADIATION PRODUCED BY COMBUSTION OF GAS, OIL, COAL OR OTHER FUELS. FEATURES MOUNT HORIZONTALLY, VERTICALLY OR AT ANY ANGLE IN BETWEEN.

Info / Ask for Price

V5197A1003

(In Stock)

GAS VALVE: V5197A1003 3/4 IN./1 IN./1 1/4 IN./1 1/2 IN./2 IN. INTEGRATED VALVE TRAIN BUTTERFLY GAS VALVE

Info / Ask for Price

V5197A1011

(In Stock)

GAS VALVE: V5197A1011 2 IN./2 1/2 IN./3 IN. INTEGRATED VALVE TRAIN BUTTERFLY GAS VALVE

Info / Ask for Price

V51E1000

(In Stock)

GAS VALVE: V51E1000 BUTTERFLY GAS VALVE, 1 1/2 IN. PIPE SIZE

Info / Ask for Price

V51E1018

(In Stock)

GAS VALVE: V51E1018 BUTTERFLY GAS VALVE, 2 IN. PIPE SIZE

Info / Ask for Price

V51E1059

(In Stock)

GAS VALVE: V51E1059 BUTTERFLY GAS VALVE, 3 IN. PIPE SIZE

Info / Ask for Price

V51E1075

(In Stock)

GAS VALVE: V51E1075 BUTTERFLY GAS VALVE, 4 IN. PIPE SIZE

Info / Ask for Price

V9055A1055

(In Stock)

GAS VALVE: V9055A1055 HONEYWELL GAS VALVE MODULATING-OFF ACTUATOR. LOW FIRE ADJUSTMENT: 5 TO 50% OF FULL. W/DAMPER SHAFT. 120V, 60HZ, 1 S CLOSE TIME OPEN TIME 26 S. ( STANDARD). USE W. V5055B, T991E/F OR 203422C 4-20 MA SIGNAL ADAPTOR.

Info / Ask for Price

SEARCH YOUR PRODUCT IN THE CATALOG