AMB24-3-S
(Trong kho)
MOUNTING BRACKET: FOR ON/OFF AND FLOATING POINT CONTROL OF DAMPERS IN HVAC SYSTEMS. ACTUATOR SIZING SHOULD BE DONE IN ACCORDANCE WITH THE DAMPER MANUFACTURERS SPECIFICATIONS. ACTUATOR IS MOUNTED DIRECTLY TO A DAMPER SHAFT UP TO 1.05 IN DIAMETER BY MEANS OF ITS UNIVERSAL CLAMP, SELF-CENTERED DEFAULT.
AMB24-3
(Trong kho)
MOUNTING BRACKET: FOR ON/OFF AND FLOATING POINT CONTROL OF DAMPERS IN HVAC SYSTEMS. ACTUATOR SIZING SHOULD BE DONE IN ACCORDANCE WITH THE DAMPER MANUFACTURERS SPECIFICATIONS. ACTUATOR IS MOUNTED DIRECTLY TO A DAMPER SHAFT UP TO 1.05 IN DIAMETER BY MEANS OF ITS UNIVERSAL CLAMP, SELF-CENTERED DEFAULT.
AMB24-SR
(Trong kho)
MOUNTING BRACKET: FOR PROPORTIONAL MODULATION OF DAMPERS IN HVAC SYSTEMS. ACTUATOR SIZING SHOULD BE DONE IN ACCORDANCE WITH DAMPER MANUFACTURERS SPECIFICATIONS. ACTUATOR IS MOUNTED DIRECTLY TO A DAMPER SHAFT UP TO 1.05” IN DIAMETER BY MEANS OF ITS UNIVERSAL CLAMP, 1/2” SELF-CENTERED DEFAULT.
NMB24-3
(Trong kho)
MOUNTING BRACKET: APPLICATION FOR NMB24-3 FOR ON/OFF AND FLOATING POINT CONTROL OF DAMPERS IN HVAC SYSTEMS. ACTUATOR SIZING SHOULD BE DONE IN ACCORDANCE WITH THE DAMPER MANUFACTURER'S SPECIFICATIONS. ACTUATOR IS MOUNTED DIRECTLY TO A DAMPER SHAFT UP TO 1.05" IN DIAMETER BY MEANS OF ITS UNIVERSAL CLAMP, 1/2 SELF-CENTERED DEFAULT.
AHB24-3-100
(Trong kho)
OVERLOAD: FOR ON/OFF AND FLOATING POINT CONTROL OF DAMPERS IN HVAC SYSTEMS. ACTUATOR SIZING SHOULD BE DONE IN ACCORDANCE WITH THE DAMPER MANUFACTURERS SPECIFICATIONS. OPERATION: ACTUATOR IS NOT PROVIDED WITH AND DOES NOT REQUIRE ANY LIMIT SWITCHES, BUT IS ELECTRONICALLY PROTECTED AGAINST OVERLOAD. ANTI-ROTATION STRAP SUPPLIED WITH ACTUATOR WILL PREVENT LATERAL MOVEMENT. AHB24
-100 PROVIDES 4 IN [100 MM] OF LINEAR STROKE. STROKE OF GEAR RACK CAN BE ADJUSTED ON BOTH SIDES IN INCREMENTS OF 0.8 IN [20 MM] BY MEANS OF MECHANICAL END STOPS. WHEN REACHING DAMPER OR ACTUATOR END POSITION, ACTUATOR AUTOMATICALLY STOPS. GEARS CAN BE MANUALLY DISENGAGED WITH A BUTTON ON ACTUATOR COVER. AHB24-3
ACTUATORS USE A SENSORLESS BRUSHLESS DC MOTOR, WHICH IS CONTROLLED BY AN APPLICATION SPECIFIC INTEGRATED CIRCUIT (ASIC). ASIC MONITORS AND CONTROLS THE ACTUATORS ROTATION AND PROVIDES A DIGITAL ROTATION SENSING (DRS) FUNCTION TO PREVENT DAMAGE TO ACTUATOR IN A STALL
AHB24-3-200
(Trong kho)
OVERLOAD: FOR ON/OFF AND FLOATING POINT CONTROL OF DAMPERS IN HVAC SYSTEMS. ACTUATOR SIZING SHOULD BE DONE IN ACCORDANCE WITH THE DAMPER MANUFACTURERS SPECIFICATIONS. OPERATION: ACTUATOR IS NOT PROVIDED WITH AND DOES NOT REQUIRE ANY LIMIT SWITCHES, BUT IS ELECTRONICALLY PROTECTED AGAINST OVERLOAD. ANTI-ROTATION STRAP SUPPLIED WITH ACTUATOR WILL PREVENT LATERAL MOVEMENT. AHB24
-200 PROVIDES 8 IN [200 MM] OF LINEAR STROKE. STROKE OF GEAR RACK CAN BE ADJUSTED ON BOTH SIDES IN INCREMENTS OF 0.8 IN [20 MM] BY MEANS OF MECHANICAL END STOPS. WHEN REACHING DAMPER OR ACTUATOR END POSITION, ACTUATOR AUTOMATICALLY STOPS. GEARS CAN BE MANUALLY DISENGAGED WITH A BUTTON ON ACTUATOR COVER. AHB24-3
ACTUATORS USE A SENSORLESS BRUSHLESS DC MOTOR, WHICH IS CONTROLLED BY AN APPLICATION SPECIFIC INTEGRATED CIRCUIT (ASIC). ASIC MONITORS AND CONTROLS THE ACTUATORS ROTATION AND PROVIDES A DIGITAL ROTATION SENSING (DRS) FUNCTION TO PREVENT DAMAGE TO ACTUATOR IN A STALL
FSAF120 US
(Trong kho)
POSITION INDICATOR: FOR TWO POSITION CONTROL OF UL555S RATED DAMPERS IN HVAC. ACTUATOR SIZING SHOULD BE DONE IN ACCORDANCE WITH DAMPER MANUFACTURERS SPECIFICATIONS.
AHB24-SR-100
(Trong kho)
POSITIONER: FOR PROPORTIONAL MODULATION OF DAMPERS IN HVAC SYSTEMS. ACTUATOR SIZING SHOULD BE DONE IN ACCORDANCE WITH THE DAMPER MANUFACTURERS SPECIFICATIONS.
AHB24-SR-200
(Trong kho)
POSITIONER: FOR PROPORTIONAL MODULATION OF DAMPERS IN HVAC SYSTEMS. ACTUATOR SIZING SHOULD BE DONE IN ACCORDANCE WITH THE DAMPER MANUFACTURERS SPECIFICATIONS.
FSLF120-S US
(Trong kho)
POWER SUPPLY: TYPE FSLF SPRING-RETURN ACTUATOR IS INTENDED FOR OPERATION OF SMOKE AND COMBINATION FIRE AND SMOKE DAMPERS IN VENTILATION AND AIR-CONDITIONING SYSTEMS. ACTUATOR WILL MEET REQUIREMENTS OF UL555 AND UL555S WHEN TESTED AS AN ASSEMBLY WITH DAMPER AND WILL MEET REQUIREMENTS OF UBC FOR 15 SECOND OPENING AND CLOSING.
FSLF120 US
(Trong kho)
POWER SUPPLY: TYPE FSLF SPRING-RETURN ACTUATOR IS INTENDED FOR OPERATION OF SMOKE AND COMBINATION FIRE AND SMOKE DAMPERS IN VENTILATION AND AIR-CONDITIONING SYSTEMS. ACTUATOR WILL MEET REQUIREMENTS OF UL555 AND UL555S WHEN TESTED AS AN ASSEMBLY WITH DAMPER AND WILL MEET REQUIREMENTS OF UBC FOR 15 SECOND OPENING AND CLOSING.
FSLF24-S US
(Trong kho)
POWER SUPPLY: TYPE FSLF SPRING-RETURN ACTUATOR IS INTENDED FOR THE OPERATION OF SMOKE AND COMBINATION FIRE AND SMOKE DAMPERS IN VENTILATION AND AIR-CONDITIONING SYSTEMS. ACTUATOR WILL MEET REQUIREMENTS OF UL555 AND UL555S WHEN TESTED AS AN ASSEMBLY WITH DAMPER AND WILL MEET REQUIREMENTS OF UBC FOR 15 SECOND OPENING AND CLOSING.
FSLF24 US
(Trong kho)
POWER SUPPLY: TYPE FSLF SPRING-RETURN ACTUATOR IS INTENDED FOR THE OPERATION OF SMOKE AND COMBINATION FIRE AND SMOKE DAMPERS IN VENTILATION AND AIR-CONDITIONING SYSTEMS. ACTUATOR WILL MEET REQUIREMENTS OF UL555 AND UL555S WHEN TESTED AS AN ASSEMBLY WITH DAMPER AND WILL MEET REQUIREMENTS OF UBC FOR 15 SECOND OPENING AND CLOSING.